MIDA 200kW DCDC Fast Charger Station Integrated with Solar PV and BESS Storage

Short Description:

200kW multi-gun DCDC solar-battery fast charger with CCS2 and CCS1 outlets and 200V-1000V DC output. OCPP 1.6J certified, IP55 outdoor enclosure, hot-swap 30kW modules and dynamic power sharing for industrial microgrids and solar carports.


Product Detail

FAQ

Product Tags

The 200kW multi-gun DCDC solar-battery fast charger targets industrial microgrids and solar carports, where uptime and quick service access decide revenue. With CCS2 and CCS1 outlets, a 200V-1000V DC window and OCPP 1.6J connectivity, it delivers predictable high-power charging while keeping installation and commissioning simple. This DC fast charging station pairs high utilisation with low maintenance overhead.

200kW DCDC converter cabinet architecture - 200kW CCS2 and CCS1

1. DCDC Solar-Battery Power Topology and Conversion Chain

An active front end feeds isolated DC/DC stages inside each cabinet, so grid harmonics stay low while output voltage follows whatever the battery management system requests. Galvanic isolation between grid and vehicle protects both sides during fault events and meets the insulation requirements behind CE and IEC 61851 compliance. Every cabinet is load tested before shipment and arrives with a wiring map covering contactors, fuses and surge arrestors for fast commissioning. Busbar layout, magnetic components and cooling channels are shared across the 200kW family, which shortens lead times and simplifies spare part stocking. Commissioning takes under an hour with the guided setup wizard. Matching power modules are documented in the datasheet.

2. 200V-1000V Wide Voltage Output With Constant Power

Cable assemblies rated 250A to 400A are matched to each outlet, and CCS2 and CCS1 leads are available in lengths from 4 to 8 metres. Voltage and current limits are negotiated over the control pilot, then confirmed by the battery management system before the DC contactors close. Wide range voltage tracking keeps efficiency above 95 percent even when a deeply depleted pack pulls close to the 250A current ceiling. Pre-charge sequencing limits inrush current, shielding vehicle contactors and DC link capacitors from stress during every plug-in. A 1000V ceiling future-proofs the investment, because the same DC fast charging station serves today’s 400V fleets and tomorrow’s 800V platforms.

Wide voltage DC output up to 1000V - 200kW CCS2 and CCS1
Hot-swappable power modules inside the charger - 200kW CCS2 and CCS1

3. 30kW Hot-Swap Power Modules and N+1 Redundancy

Thermal design holds junction temperatures stable at 50 degrees ambient, so the DC fast charger sustains rated output in hot climates. N plus one redundancy keeps rated 200kW available even while one module is pulled for service, which matters on revenue-critical corridors. Speed-controlled fans and intelligent airflow keep acoustic noise near 65 dB, which suits residential, hospital and retail locations. Module-level diagnostics flag degrading fans and capacitors long before they cause a stoppage, enabling condition-based maintenance. Modules slide out from the front, so service engineers never need rear clearance in tight parking layouts or wall-adjacent installations. Compatible EV charging connectors are listed separately.

4. Dynamic Power Allocation Across Dual Outlets

Session logs record delivered energy per outlet, which simplifies billing, reconciliation and fleet cost allocation. Dynamic power allocation distributes available capacity across outlets in real time, letting a single vehicle draw the full 200kW. When a second connector activates, the controller splits output according to state of charge rather than a fixed schedule. Because capacity follows demand, the DC fast charging station avoids the idle-outlet penalty that drags down utilisation on paired connectors. Matrix switching allows any module to serve any gun, so one cabinet can run a single 250A session or two lower-current sessions. Site rules are tuned from the operator portal.

Dynamic power sharing between charging guns - 200kW CCS2 and CCS1
Weatherproof outdoor charging cabinet - 200kW CCS2 and CCS1

5. Outdoor IP55 Enclosure Built for Public Sites

Optional heating, ventilation and lighting kits extend operation to cold storage yards and dusty mining roads. A powder-coated steel body with anti-corrosion treatment suits coastal, industrial and roadside installations. Front and side service access is available, and the base frame accepts either anchor bolts or a concrete plinth. Ambient range runs from minus 30 to plus 55 degrees Celsius, with internal heaters protecting the 7-inch display in freezing conditions. Surge protection, residual current detection and emergency stop are integrated, and the cabinet is engineered for a ten-year outdoor service life. Each unit is ingress tested at the factory and ships with CE documentation covering insulation and earth continuity checks. Installation drawings cover plinth and cable routing.

6. Smart Payment, OCPP Management and Energy Integration

OCPP 1.6J adds certificate handling and stronger message security for public networks that must satisfy national roaming rules. Local storage keeps sessions running if connectivity drops, then synchronises records once the link returns. Communication runs over OCPP 1.6J, so the station integrates with almost any back office without custom middleware. Every session produces a metered record covering start, stop and energy delivered, mapping directly to the operator’s billing engine. Remote diagnostics, firmware updates and tariff changes are pushed over the air, cutting truck rolls for routine maintenance. The controller exposes smart charging profiles, so a central system can cap site load during peak tariff periods. Backend integration follows the OCPP specification.

Payment terminal and OCPP network controller - 200kW CCS2 and CCS1

Deployment Support and Accessories

Projects usually pair the cabinet with Type 2 to Type 2 cables and a OCPP protocol controllers, all supplied from one factory. Engineering teams can review the company profile before order, while commercial questions go through the contact our team page. Standard builds ship in four to six weeks, and documentation covers wiring, grounding and network setup.

Frequently Asked Questions

What output voltage range does the 200kW unit support?

The charger delivers 200V to 1000V DC at up to 250A, so it serves 400V passenger cars and 800V heavy vehicles from the same outlet. Constant power holds 200kW from about 500V upward, which shortens charging time on modern high-voltage packs.

How does DCDC architecture differ from a conventional AC-DC charger?

A DCDC stage accepts a DC bus from solar or battery storage and converts it directly, skipping one rectification step. That raises round-trip efficiency and lets the DCDC solar-battery platform operate during grid outages when paired with a BESS cabinet.

Can the two guns charge at the same time at full power?

Yes, with dynamic allocation. Total capacity is shared, so one vehicle can take the full 200kW, or two vehicles can split it according to state of charge. Matrix switching means any module can serve either outlet, and rules are configured remotely.

Which OCPP version should an operator choose?

OCPP 1.6J covers the widest installed base of back offices today. OCPP 1.6J is specified here for certificate handling, plug and charge support and stronger message security. Both profiles work with standard roaming hubs, and the protocol controller datasheet explains the mapping.

What protection level is needed for roadside installation?

IP55 is the baseline for outdoor public sites, combined with surge arrestors, residual current detection and an emergency stop. Coastal or dusty locations should add the anti-corrosion coating and filter service kit.

How is maintenance handled when a power module fails?

Modules are hot-swappable from the front. A technician isolates the affected unit, slides it out and seats a pre-calibrated replacement while the second outlet keeps serving traffic. N plus one redundancy keeps rated output available throughout.

Does the station support solar and battery storage integration?

The DC bus is storage-ready. Solar MPPT or a BESS cabinet can feed the link directly, and the controller can cap grid import during peak tariffs. This suits microgrid and carport projects where demand charges dominate operating cost.

What payment options are available for public drivers?

RFID card, mobile app, QR code, ISO 15118 plug and charge and an optional POS terminal for contactless bank cards. All methods write to the same metered session record, so reconciliation stays simple. Connector options are listed on our EV charging connector page.

As a commercial DC fast charger, the platform is specified for operators who need predictable uptime from a DC fast charging station.

Fleet managers comparing a DC fast charging station against split systems value the single-cabinet service model of this DC fast charger.

The DC fast charging station ships with commissioning support, and every DC fast charger is backed by regional spares.

Choosing a DC fast charger with documented test reports keeps procurement audits simple for any commercial EV charger project.

As a commercial DC fast charger, the platform is specified for operators who need predictable uptime from a DC fast charging station.









  • Previous:
  • Next:

  • Write your message here and send it to us