MIDA 200kW DC Fast Charging Station Dual Gun CCS2 for Commercial EV Hub CE

Short Description:

200kW dual-gun DC fast charging station for public parking hubs and retail destinations. CCS2 connectors, 200V-1000V wide voltage output at 250A, hot-swappable 30kW modules, OCPP 1.6J and IP55 rated enclosure with RFID, app and POS payment.


Product Detail

FAQ

Product Tags

The 200kW dual-gun modular AC-DC fast charger targets public parking hubs and retail destinations, where uptime and quick service access decide revenue. With CCS2 outlets, a 200V-1000V DC window and OCPP 1.6J connectivity, it delivers predictable high-power charging while keeping installation and commissioning simple. This DC fast charging station pairs high utilisation with low maintenance overhead.

200kW DCDC converter cabinet architecture - 200kW CCS2

1. Modular AC-DC Power Topology and Conversion Chain

Bidirectional-ready bus design lets the same platform accept solar or battery energy storage input without a second conversion stage. Power conversion is separated from control logic, so firmware updates and diagnostics never interrupt an active charging session. Busbar layout, magnetic components and cooling channels are shared across the 200kW family, which shortens lead times and simplifies spare part stocking. Galvanic isolation between grid and vehicle protects both sides during fault events and meets the insulation requirements behind CE and IEC 61851 compliance. Efficiency peaks at 96 percent and stays above 94 percent from light load to full output, cutting energy cost for high-utilisation sites. Matching power modules are documented in the datasheet.

2. 200V-1000V Wide Voltage Output With Constant Power

Cable assemblies rated 250A to 400A are matched to each outlet, and CCS2 leads are available in lengths from 4 to 8 metres. Continuous insulation monitoring isolates the outlet whenever leakage approaches the configured threshold, protecting technicians and vehicles alike. Pre-charge sequencing limits inrush current, shielding vehicle contactors and DC link capacitors from stress during every plug-in. Voltage and current limits are negotiated over the control pilot, then confirmed by the battery management system before the DC contactors close. Constant power operation holds the full 200kW from roughly 500V upward, so an 800V pack charges at rated rate instead of tapering early.

Wide voltage DC output up to 1000V - 200kW CCS2
Hot-swappable power modules inside the charger - 200kW CCS2

3. 30kW Hot-Swap Power Modules and N+1 Redundancy

Power is delivered by 30kW hot-swappable modules, so a failed unit is exchanged in minutes without isolating the whole cabinet. Speed-controlled fans and intelligent airflow keep acoustic noise near 65 dB, which suits residential, hospital and retail locations. N plus one redundancy keeps rated 200kW available even while one module is pulled for service, which matters on revenue-critical corridors. Each module reports voltage, current, temperature and fan speed to the controller, which derates or isolates any unit drifting out of tolerance. Modules slide out from the front, so service engineers never need rear clearance in tight parking layouts or wall-adjacent installations. Compatible EV charging connectors are listed separately.

4. Dynamic Power Allocation Across Dual Outlets

Operators set allocation rules per site, per connector or per tariff window through the cloud portal, with no on-site reprogramming. Priority rules can reserve one outlet for emergency fleets while the other follows a normal queue, all configured remotely. Because capacity follows demand, the DC fast charging station avoids the idle-outlet penalty that drags down utilisation on paired connectors. Scheduling profiles prioritise buses in the morning and light vehicles in the evening without manual intervention. Matrix switching allows any module to serve any gun, so one cabinet can run a single 250A session or two lower-current sessions. Site rules are tuned from the operator portal.

Dynamic power sharing between charging guns - 200kW CCS2
Weatherproof outdoor charging cabinet - 200kW CCS2

5. Outdoor IP55 Enclosure Built for Public Sites

Optional heating, ventilation and lighting kits extend operation to cold storage yards and dusty mining roads. Ambient range runs from minus 30 to plus 55 degrees Celsius, with internal heaters protecting the 7-inch display in freezing conditions. Each unit is ingress tested at the factory and ships with CE documentation covering insulation and earth continuity checks. Surge protection, residual current detection and emergency stop are integrated, and the cabinet is engineered for a ten-year outdoor service life. The bonded anti-glare touchscreen stays readable in direct sunlight and remains responsive through gloved operation. A powder-coated steel body with anti-corrosion treatment suits coastal, industrial and roadside installations. Installation drawings cover plinth and cable routing.

6. Smart Payment, OCPP Management and Energy Integration

Multi-language interface, configurable tariff screens and branded start pages help operators monetise the charging session itself. OCPP 1.6J adds certificate handling and stronger message security for public networks that must satisfy national roaming rules. Drivers authenticate by RFID card, mobile app, QR code or ISO 15118 plug and charge, with an optional POS terminal for bank card payment. The controller exposes smart charging profiles, so a central system can cap site load during peak tariff periods. Local storage keeps sessions running if connectivity drops, then synchronises records once the link returns. Remote diagnostics, firmware updates and tariff changes are pushed over the air, cutting truck rolls for routine maintenance. Backend integration follows the OCPP specification.

Payment terminal and OCPP network controller - 200kW CCS2

Deployment Support and Accessories

Projects usually pair the cabinet with Type 2 to Type 2 cables and a OCPP protocol controllers, all supplied from one factory. Engineering teams can review the company profile before order, while commercial questions go through the contact our team page. Standard builds ship in four to six weeks, and documentation covers wiring, grounding and network setup.

Frequently Asked Questions

What payment options are available for public drivers?

RFID card, mobile app, QR code, ISO 15118 plug and charge and an optional POS terminal for contactless bank cards. All methods write to the same metered session record, so reconciliation stays simple. Connector options are listed on our EV charging connector page.

What output voltage range does the 200kW unit support?

The charger delivers 200V to 1000V DC at up to 250A, so it serves 400V passenger cars and 800V heavy vehicles from the same outlet. Constant power holds 200kW from about 500V upward, which shortens charging time on modern high-voltage packs.

How does DCDC architecture differ from a conventional AC-DC charger?

A DCDC stage accepts a DC bus from solar or battery storage and converts it directly, skipping one rectification step. That raises round-trip efficiency and lets the modular AC-DC platform operate during grid outages when paired with a BESS cabinet.

Can the two guns charge at the same time at full power?

Yes, with dynamic allocation. Total capacity is shared, so one vehicle can take the full 200kW, or two vehicles can split it according to state of charge. Matrix switching means any module can serve either outlet, and rules are configured remotely.

Which OCPP version should an operator choose?

OCPP 1.6J covers the widest installed base of back offices today. OCPP 1.6J is specified here for certificate handling, plug and charge support and stronger message security. Both profiles work with standard roaming hubs, and the protocol controller datasheet explains the mapping.

What protection level is needed for roadside installation?

IP55 is the baseline for outdoor public sites, combined with surge arrestors, residual current detection and an emergency stop. Coastal or dusty locations should add the anti-corrosion coating and filter service kit.

As a commercial DC fast charger, the platform is specified for operators who need predictable uptime from a DC fast charging station.

Fleet managers comparing a DC fast charging station against split systems value the single-cabinet service model of this DC fast charger.

The DC fast charging station ships with commissioning support, and every DC fast charger is backed by regional spares.

Choosing a DC fast charger with documented test reports keeps procurement audits simple for any commercial EV charger project.

As a commercial DC fast charger, the platform is specified for operators who need predictable uptime from a DC fast charging station.









  • Previous:
  • Next:

  • Write your message here and send it to us