90kW Commercial DC Fast Charging Pile Floor Standing Dual Guns OCPP 1.6J CE Listed

Short Description:

Modular AC-DC 90kW dual-gun EV charger built for public parking hubs and retail destinations: CCS2 and CCS1 outputs, 1000V constant power, hot-swap 20kW modules, dynamic load sharing, OCPP 1.6J backend integration and IP55 weatherproof housing.


Product Detail

FAQ

Product Tags

The 90kW dual-gun modular AC-DC fast charger targets public parking hubs and retail destinations, where uptime and quick service access decide revenue. With CCS2 and CCS1 outlets, a 200V-1000V DC window and OCPP 1.6J connectivity, it delivers predictable high-power charging while keeping installation and commissioning simple. This DC fast charging station pairs high utilisation with low maintenance overhead.

90kW DCDC converter cabinet architecture - 90kW CCS2 and CCS1

1. Modular AC-DC Power Topology and Conversion Chain

Galvanic isolation between grid and vehicle protects both sides during fault events and meets the insulation requirements behind CE and IEC 61851 compliance. Bidirectional-ready bus design lets the same platform accept solar or battery energy storage input without a second conversion stage. Every cabinet is load tested before shipment and arrives with a wiring map covering contactors, fuses and surge arrestors for fast commissioning. Efficiency peaks at 96 percent and stays above 94 percent from light load to full output, cutting energy cost for high-utilisation sites. Input power factor stays above 0.99 and the wide input window keeps operation stable on weak rural feeders and long industrial spurs. Matching power modules are documented in the datasheet.

2. 200V-1000V Wide Voltage Output With Constant Power

Voltage and current limits are negotiated over the control pilot, then confirmed by the battery management system before the DC contactors close. A 1000V ceiling future-proofs the investment, because the same DC fast charging station serves today’s 400V fleets and tomorrow’s 800V platforms. Constant power operation holds the full 90kW from roughly 500V upward, so an 800V pack charges at rated rate instead of tapering early. Precision metering at the outlet delivers Class B accuracy, so billed energy matches what the vehicle actually receives. Continuous insulation monitoring isolates the outlet whenever leakage approaches the configured threshold, protecting technicians and vehicles alike.

Wide voltage DC output up to 1000V - 90kW CCS2 and CCS1
Hot-swappable power modules inside the charger - 90kW CCS2 and CCS1

3. 20kW Hot-Swap Power Modules and N+1 Redundancy

Thermal design holds junction temperatures stable at 50 degrees ambient, so the DC fast charger sustains rated output in hot climates. A shared DC bus lets any module feed any outlet, removing the fixed pairing that limits conventional charging piles. Speed-controlled fans and intelligent airflow keep acoustic noise near 65 dB, which suits residential, hospital and retail locations. Each module reports voltage, current, temperature and fan speed to the controller, which derates or isolates any unit drifting out of tolerance. Modules slide out from the front, so service engineers never need rear clearance in tight parking layouts or wall-adjacent installations. Compatible EV charging connectors are listed separately.

4. Dynamic Power Allocation Across Dual Outlets

Because capacity follows demand, the DC fast charging station avoids the idle-outlet penalty that drags down utilisation on paired connectors. Dynamic power allocation distributes available capacity across outlets in real time, letting a single vehicle draw the full 90kW. Scheduling profiles prioritise buses in the morning and light vehicles in the evening without manual intervention. Operators set allocation rules per site, per connector or per tariff window through the cloud portal, with no on-site reprogramming. Matrix switching allows any module to serve any gun, so one cabinet can run a single 125A session or two lower-current sessions. Site rules are tuned from the operator portal.

Dynamic power sharing between charging guns - 90kW CCS2 and CCS1
Weatherproof outdoor charging cabinet - 90kW CCS2 and CCS1

5. Outdoor IP55 Enclosure Built for Public Sites

Front and side service access is available, and the base frame accepts either anchor bolts or a concrete plinth. The bonded anti-glare touchscreen stays readable in direct sunlight and remains responsive through gloved operation. Surge protection, residual current detection and emergency stop are integrated, and the cabinet is engineered for a ten-year outdoor service life. Ambient range runs from minus 30 to plus 55 degrees Celsius, with internal heaters protecting the 7-inch display in freezing conditions. A powder-coated steel body with anti-corrosion treatment suits coastal, industrial and roadside installations. The enclosure is rated IP55, with filtered intake louvres and a sealed electronics compartment that shrugs off rain, dust and washdown. Installation drawings cover plinth and cable routing.

6. Smart Payment, OCPP Management and Energy Integration

Drivers authenticate by RFID card, mobile app, QR code or ISO 15118 plug and charge, with an optional POS terminal for bank card payment. The controller exposes smart charging profiles, so a central system can cap site load during peak tariff periods. OCPP 1.6J adds certificate handling and stronger message security for public networks that must satisfy national roaming rules. Every session produces a metered record covering start, stop and energy delivered, mapping directly to the operator’s billing engine. Multi-language interface, configurable tariff screens and branded start pages help operators monetise the charging session itself. Local storage keeps sessions running if connectivity drops, then synchronises records once the link returns. Backend integration follows the OCPP specification.

Payment terminal and OCPP network controller - 90kW CCS2 and CCS1

Deployment Support and Accessories

Projects usually pair the cabinet with Type 2 to Type 2 cables and a OCPP protocol controllers, all supplied from one factory. Engineering teams can review the company profile before order, while commercial questions go through the contact our team page. Standard builds ship in four to six weeks, and documentation covers wiring, grounding and network setup.

Frequently Asked Questions

What output voltage range does the 90kW unit support?

The charger delivers 200V to 1000V DC at up to 125A, so it serves 400V passenger cars and 800V heavy vehicles from the same outlet. Constant power holds 90kW from about 500V upward, which shortens charging time on modern high-voltage packs.

How does DCDC architecture differ from a conventional AC-DC charger?

A DCDC stage accepts a DC bus from solar or battery storage and converts it directly, skipping one rectification step. That raises round-trip efficiency and lets the modular AC-DC platform operate during grid outages when paired with a BESS cabinet.

Can the two guns charge at the same time at full power?

Yes, with dynamic allocation. Total capacity is shared, so one vehicle can take the full 90kW, or two vehicles can split it according to state of charge. Matrix switching means any module can serve either outlet, and rules are configured remotely.

Which OCPP version should an operator choose?

OCPP 1.6J covers the widest installed base of back offices today. OCPP 1.6J is specified here for certificate handling, plug and charge support and stronger message security. Both profiles work with standard roaming hubs, and the protocol controller datasheet explains the mapping.

What protection level is needed for roadside installation?

IP55 is the baseline for outdoor public sites, combined with surge arrestors, residual current detection and an emergency stop. Coastal or dusty locations should add the anti-corrosion coating and filter service kit.

How is maintenance handled when a power module fails?

Modules are hot-swappable from the front. A technician isolates the affected unit, slides it out and seats a pre-calibrated replacement while the second outlet keeps serving traffic. N plus one redundancy keeps rated output available throughout.

Does the station support solar and battery storage integration?

The DC bus is storage-ready. Solar MPPT or a BESS cabinet can feed the link directly, and the controller can cap grid import during peak tariffs. This suits microgrid and carport projects where demand charges dominate operating cost.

As a commercial DC fast charger, the platform is specified for operators who need predictable uptime from a DC fast charging station.

Fleet managers comparing a DC fast charging station against split systems value the single-cabinet service model of this DC fast charger.

The DC fast charging station ships with commissioning support, and every DC fast charger is backed by regional spares.

Choosing a DC fast charger with documented test reports keeps procurement audits simple for any commercial EV charger project.









  • Previous:
  • Next:

  • Write your message here and send it to us